- Detailed Photos
Basic Info.
Model NO.
GSC1-kd
Theory
Electromagnetic Relay
Size
Miniature
Operation ambient temperature
-25 to +60 centigrade
Storage temperature
-40 to +70 centigrade
Altitude
3000m
Class of pollution
3
Installation category
3
Transport Package
Carton
Specification
IEC60947-4-1
Trademark
TIANSHUI 213
Origin
China
HS Code
8536490090
Production Capacity
80000PCS/Year
Product Description
GSC1-kd series of capacitor changeover contactor is used in the circuit of AC 50Hz(or 60Hz), rated insulation voltage up to 690V, rated current is from 18A up to 87A for AC-6b at rated voltage of 400V to 440V for the purpose of closing or breaking capacitor bank, which is used for low voltage reactive power compensation, and then adjusting power factor value of power system. Contactor with inrush current suppression device can effectively reduce the impact on capacitor bank from switching inrush current and reduce operation over-voltage.
Model | CJX4~25kd | CJX4~32kd | CJX4~40kd | CJX4~50kd | CJX4~60kd | CJX4~80kd | CJX4~100kd | CJX4~125kd | ||
Electrical parameters | ||||||||||
Rated insulation voltage Ui (V) | 690 | |||||||||
Rated voltage Ue (V) | 220-240V/400-440V | |||||||||
Conventional thermal current Ith (A) (AC-6b) | 25 | 32 | 40 | 50 | 60 | 80 | 100 | 125 | ||
Rated current Ie (A) | AC-6b | 220-240V | 18 | 24 | 29 | 36 | 48 | 58 | 72 | 87 |
400-440V | 18 | 24 | 29 | 36 | 48 | 58 | 72 | 87 | ||
controlled power (Kvar) | AC-6b | 220-240V | 6.7 | 8.5 | 10 | 15 | 20 | 25 | 25 | 40 |
400-440V | 12.5 | 16.7 | 20 | 25 | 33.3 | 40 | 50 | 60 | ||
Inrush current suppression capacity (times) | 15 | |||||||||
Contact quantity | 3P+2NO/3P+2NC/3P+1NC+1NC | 3P+2NO+1NC/3P+1NO+2NC | ||||||||
Auxiliary contact | ||||||||||
Rated Voltage Ue (V) | AC 380V, DC 220V | |||||||||
Conventional thermal current Ith (A) | 10 | |||||||||
Rated current Ie (A) | AC-15 (360VA) | 0.95 | ||||||||
DC-13 (33W) | 0.15 | |||||||||
Mini. load | 24V 10mA | |||||||||
Coil | ||||||||||
Standard coil voltage Us (V) | 24V, 36V, 48V, 110V , 220V, 380V (50Hz/60Hz) | |||||||||
Pull-in voltage (V) | 0.85US-1.10Us (-25 to +60 centigrade) | |||||||||
Drop-out voltage (V) | 0.20Us-0.75Us (-25 to +60 centigrade) | |||||||||
Pull-in power (VA) | 76 | 110 | 230 | |||||||
Hold power (VA) | 10 | 11 | 32 | |||||||
AC-6b | Electrical life (10000 times) | 12 | 12 | 10 | 10 | 10 | 10 | 10 | 10 | |
Operation frequency per hour | 300 | 300 | 300 | 300 | 120 | 120 | 120 | 120 | ||
Mechanical life (10000 times) | 300 | |||||||||
Standard | IEC60947-4-1, EN60947-4-1 | |||||||||
Certificate | CE | |||||||||
Operation ambient temperature | -25 to +60 centigrade | |||||||||
Storage temperature | -40 to +70 centigrade | |||||||||
Altitude (m) | 3000m, if higher than 3000m, then derate | |||||||||
Class of pollution | 3 | |||||||||
Installation category | 3 | |||||||||
Net weight (KG) | 0.44 | 0.63 | 1.31 | 1.52 |